![]() Same vessel, Annual pump inspection and replaced all anodes Hamilton Jet Drives: Removed and rebuilt both jets on government's vessel The elbow was replaced as well as the back-end generator and the unit is now back in operation. Inspection revealed the mixing elbow had corroded to the point that raw water was spraying onto the generator windings. Westerbeke 8KW Genset Part III: Client called in with problem of genset not producing any power. The injector pump was pulled and rebuilt, now the genset starts with ease and power all AirCon unit including the stove. Owner stated the genset “had always been like that”. Upon inspection of the unit, it was noted the unit was set to the wrong frequency but also that it was VERY slow to start. Westerbeke 8KW Genset Part II: Client called in with genset problem of not holding a load of its AirCon units or its electric stove. Sensor was replaced and unit was fully operational again. An inspection of the electrical system showed the Coolant Temperature sensor was shorted out. Westerbeke 8KW Genset Part I: Client called in with problem of engine shuts down approximately 30 seconds after starting. The pump was rebuilt, re-installed and the genset now operates, and shuts down properly. ![]() After an inspection and some dis-assembly quickly revealed the injector pump had seized. ![]() Onan 12KW Genset: Another client called in with problem of “Cannot get genset to shut down without blocking off the air intake”. ![]()